Heater switching in blister packaging - GavazziAutomation
Skip to Content
Vetrina Carlo Gavazzi
Hero BannerEnergie-to-Components
Il Gruppo Carlo Gavazzi

Torna alla panoramica

Heater switching in blister packaging

RF1A23D25

1-pole panel mount SSR, Zero-cross switching, Operating voltage (Ue): 24 - 280 Vac (600 Vp), Rated current (Ie): 25 Aac, Control voltage (Uc): 18 - 28.8 Vdc, Built-in overvoltage protection, Certified (EN60335-1), Packed x10

Dettagli e acquistaScheda tecnica

RF1A23D25X100

1-pole panel mount SSR, Zero-cross switching, Operating voltage (Ue): 24 - 280 Vac (600 Vp), Rated current (Ie): 25 Aac, Control voltage (Uc): 18 - 28.8 Vdc, Built-in overvoltage protection, Certified (EN60335-1), Packed x100

RF1A23L25

1-pole panel mount SSR, Zero-cross switching, Operating voltage (Ue): 24 - 280 Vac (600 Vp), Rated current (Ie): 25 Aac, Control voltage (Uc): 4.25 - 9 Vdc, Built-in overvoltage protection, Certified (EN60335-1), Packed x10

RF1A23L25X100

1-pole panel mount SSR, Zero-cross switching, Operating voltage (Ue): 24 - 280 Vac (600 Vp), Rated current (Ie): 25 Aac, Control voltage (Uc): 4.25 - 9 Vdc, Built-in overvoltage protection, Certified (EN60335-1), Packed x100

RF1A23M25

1-pole panel mount SSR, Zero-cross switching, Operating voltage (Ue): 24 - 280 Vac (600 Vp), Rated current (Ie): 25 Aac, Control voltage (Uc): 9 - 18 Vdc, Built-in overvoltage protection, Certified (EN60335-1), Packed x10

RF1A23M25X100

1-pole panel mount SSR, Zero-cross switching, Operating voltage (Ue): 24 - 280 Vac (600 Vp), Rated current (Ie): 25 Aac, Control voltage (Uc): 9 - 18 Vdc, Built-in overvoltage protection, Certified (EN60335-1), Packed x100

RKD2A23D50C

2-pole panel mount SSR, Zero-cross switching, dual control, Operating voltage (Ue): 24 - 265 Vac (600 Vp), Rated current (Ie): 50 Aac, Control voltage (Uc): 4 - 32 Vdc, Built-in overvoltage protection, Certified (EN60335-1)

RKD2A23D50P

2-pole panel mount SSR, Zero-cross switching, dual control, Operating voltage (Ue): 24 - 265 Vac (600 Vp), Rated current (Ie): 50 Aac, Control voltage (Uc): 4 - 32 Vdc, Built-in overvoltage protection, Certified (EN60335-1)

RKD2A60D50C

2-pole panel mount SSR, Zero-cross switching, dual control, Operating voltage (Ue): 42 - 660 Vac (1200 Vp), Rated current (Ie): 50 Aac, Control voltage (Uc): 4 - 32 Vdc, Built-in overvoltage protection, Certified (EN60335-1)

RKD2A60D50CX30

2-pole panel mount SSR, Zero-cross switching, dual control, Operating voltage (Ue): 42 - 660 Vac (1200 Vp), Rated current (Ie): 50 Aac, Control voltage (Uc): 4 - 32 Vdc, Built-in overvoltage protection, Certified (EN60335-1), Packed x30

RKD2A60D50P

2-pole panel mount SSR, Zero-cross switching, dual control, Operating voltage (Ue): 42 - 660 Vac (1200 Vp), Rated current (Ie): 50 Aac, Control voltage (Uc): 4 - 32 Vdc, Built-in overvoltage protection, Certified (EN60335-1)

RKD2A60D51C

2-pole panel mount SSR, Zero-cross switching, dual control, Operating voltage (Ue): 42 - 660 Vac (1200 Vp), Rated current (Ie): 50 Aac, Control voltage (Uc): 4 - 32 Vdc, Built-in overvoltage protection, Certified (EN 60335-1), High I2t

Assistenza e contatti

+39 02 931 76 1Invia e-mailSito web di CG Holding

Chi siamo

Lingua

Italy

Italian

© 2025 Carlo Gavazzi