RKD2A23D50C

2-pole panel mount SSR, Zero-cross switching, dual control, Operating voltage (Ue): 24 - 265 Vac (600 Vp), Rated current (Ie): 50 Aac, Control voltage (Uc): 4 - 32 Vdc, Built-in overvoltage protection, Certified (EN60335-1)

Dettagli e acquistaScheda tecnica

RKD2A23D50P

2-pole panel mount SSR, Zero-cross switching, dual control, Operating voltage (Ue): 24 - 265 Vac (600 Vp), Rated current (Ie): 50 Aac, Control voltage (Uc): 4 - 32 Vdc, Built-in overvoltage protection, Certified (EN60335-1)

RKD2A60D50C

2-pole panel mount SSR, Zero-cross switching, dual control, Operating voltage (Ue): 42 - 660 Vac (1200 Vp), Rated current (Ie): 50 Aac, Control voltage (Uc): 4 - 32 Vdc, Built-in overvoltage protection, Certified (EN60335-1)

RKD2A60D50CX30

2-pole panel mount SSR, Zero-cross switching, dual control, Operating voltage (Ue): 42 - 660 Vac (1200 Vp), Rated current (Ie): 50 Aac, Control voltage (Uc): 4 - 32 Vdc, Built-in overvoltage protection, Certified (EN60335-1), Packed x30

RKD2A60D50P

2-pole panel mount SSR, Zero-cross switching, dual control, Operating voltage (Ue): 42 - 660 Vac (1200 Vp), Rated current (Ie): 50 Aac, Control voltage (Uc): 4 - 32 Vdc, Built-in overvoltage protection, Certified (EN60335-1)

RKD2A60D51C

2-pole panel mount SSR, Zero-cross switching, dual control, Operating voltage (Ue): 42 - 660 Vac (1200 Vp), Rated current (Ie): 50 Aac, Control voltage (Uc): 4 - 32 Vdc, Built-in overvoltage protection, Certified (EN 60335-1), High I2t

RKD2A60D51P

2-pole panel mount SSR, Zero-cross switching, dual control, Operating voltage (Ue): 42 - 660 Vac (1200 Vp), Rated current (Ie): 50 Aac, Control voltage (Uc): 4 - 32 Vdc, Built-in overvoltage protection, Certified (EN 60335-1), High I2t

RKD2A60D75C

2-pole panel mount SSR, Zero-cross switching, dual control, Operating voltage (Ue): 42 - 660 Vac (1200 Vp), Rated current (Ie): 75 Aac, Control voltage (Uc): 4 - 32 Vdc, Built-in overvoltage protection, Certified (EN60335-1)

RKD2A60D75P

2-pole panel mount SSR, Zero-cross switching, dual control, Operating voltage (Ue): 42 - 660 Vac (1200 Vp), Rated current (Ie): 75 Aac, Control voltage (Uc): 4 - 32 Vdc, Built-in overvoltage protection, Certified (EN60335-1)

RKD2B60D50P

2-pole panel mount SSR, Instant-on switching, dual control, Operating voltage (Ue): 42 - 660 Vac (1200 Vp), Rated current (Ie): 50 Aac, Control voltage (Uc): 4 - 32 Vdc, Built-in overvoltage protection, Certified (EN60335-1)

RKD2B60D75P

2-pole panel mount SSR, Instant-on switching, dual control, Operating voltage (Ue): 42 - 660 Vac (1200 Vp), Rated current (Ie): 75 Aac, Control voltage (Uc): 4 - 32 Vdc, Built-in overvoltage protection, Certified (EN60335-1)