RM1A and RM1B for heater and motor switching - GavazziAutomation
Skip to Content
Vetrina Carlo Gavazzi
Hero BannerEnergie-to-Components
Il Gruppo Carlo Gavazzi

Torna alla panoramica

RM1A and RM1B for heater and motor switching

RM1A23A100

1-pole panel mount SSR, Zero-cross switching, Operating voltage (Ue): 24 - 265 Vac (650 Vp), Rated current (Ie): 100 Aac, Control voltage (Uc): 20 - 280 Vac / 22 - 48 Vdc, Built-in overvoltage protection

Dettagli e acquistaScheda tecnica

RM1A23A25

1-pole panel mount SSR, Zero-cross switching, Operating voltage (Ue): 24 - 265 Vac (650 Vp), Rated current (Ie): 25 Aac, Control voltage (Uc): 20 - 280 Vac / 22 - 48 Vdc, Built-in overvoltage protection

RM1A23A50

1-pole panel mount SSR, Zero-cross switching, Operating voltage (Ue): 24 - 265 Vac (650 Vp), Rated current (Ie): 50 Aac, Control voltage (Uc): 20 - 280 Vac / 22 - 48 Vdc, Built-in overvoltage protection

RM1A23A75

1-pole panel mount SSR, Zero-cross switching, Operating voltage (Ue): 24 - 265 Vac (650 Vp), Rated current (Ie): 75 Aac, Control voltage (Uc): 20 - 280 Vac / 22 - 48 Vdc, Built-in overvoltage protection

RM1A23D100

1-pole panel mount SSR, Zero-cross switching, Operating voltage (Ue): 24 - 265 Vac (650 Vp), Rated current (Ie): 100 Aac, Control voltage (Uc): 3 - 32 Vdc, Built-in overvoltage protection

RM1A23D25

1-pole panel mount SSR, Zero-cross switching, Operating voltage (Ue): 24 - 265 Vac (650 Vp), Rated current (Ie): 25 Aac, Control voltage (Uc): 3 - 32 Vdc, Built-in overvoltage protection

RM1A23D50

1-pole panel mount SSR, Zero-cross switching, Operating voltage (Ue): 24 - 265 Vac (650 Vp), Rated current (Ie): 50 Aac, Control voltage (Uc): 3 - 32 Vdc, Built-in overvoltage protection

RM1A23D75

1-pole panel mount SSR, Zero-cross switching, Operating voltage (Ue): 24 - 265 Vac (650 Vp), Rated current (Ie): 75 Aac, Control voltage (Uc): 3 - 32 Vdc, Built-in overvoltage protection

RM1A40A100

1-pole panel mount SSR, Zero-cross switching, Operating voltage (Ue): 42 - 440 Vac (800 Vp), Rated current (Ie): 100 Aac, Control voltage (Uc): 20 - 280 Vac / 22 - 48 Vdc, Built-in overvoltage protection

RM1A40A25

1-pole panel mount SSR, Zero-cross switching, Operating voltage (Ue): 42 - 440 Vac (800 Vp), Rated current (Ie): 25 Aac, Control voltage (Uc): 20 - 280 Vac / 22 - 48 Vdc, Built-in overvoltage protection

RM1A40A50

1-pole panel mount SSR, Zero-cross switching, Operating voltage (Ue): 42 - 440 Vac (800 Vp), Rated current (Ie): 50 Aac, Control voltage (Uc): 20 - 280 Vac / 22 - 48 Vdc, Built-in overvoltage protection

RM1A40A75

1-pole panel mount SSR, Zero-cross switching, Operating voltage (Ue): 42 - 440 Vac (800 Vp), Rated current (Ie): 75 Aac, Control voltage (Uc): 20 - 280 Vac / 22 - 48 Vdc, Built-in overvoltage protection